Grain moisture meter SUPERTECH SuperPro
Purpose and scope:
Grain moisture meter SUPERTECH SuperPro is designed for express control of the moisture content of grain and seeds of agricultural crops.
Cereal crops: corn, wheat, rye, barley, oats, buckwheat, rice, sorghum, millet.
Legumes: peas, soybeans, clover.
Oilseeds: sunflower, rapeseed, flax, mustard.
Processed products: flour, semolina.
Description:
This is a handy, portable electronic device in which moisture content readings are displayed as a percentage on an electronic display. Uses resistive measurement principle. When working with the device, preliminary grinding of the sample is not required.
Principle of operation: the sample is placed in the measuring cylinder, the cap is screwed up to the stop. The cover has millstones that provides compression and crushing of a sample. This contributes to obtaining homogenized samples, which leads to a decrease in the moisture measurement error of no more than 0.3-0.5%.
The device performs automatic temperature compensation and averages the measurement results if several measurements of the same product are taken in a row.
Moisture meter SuperPro is identical to the moisture meter FarmPro in terms of characteristics and principle of operation, but differs primarily in its design for comfortable placement in the palm of your hand, as well as an enlarged backlit display.
Specifications
Model | FarmPoint | FarmPro | SuperPoint | SuperPro |
Type | portable | portable | portable | portable |
Measurement type | dielcometric | resistive | dielcometric | resistive |
Sample preparation | without grinding | with grinding | without grinding | with grinding |
Number of calibrations | 19 | 19 | 20 | 20 |
Measurement range, % | 5…45 | 5…50 | 5…45 | 5…50 |
Permissible values of absolute measurement error: | ||||
– in the range up to 18-20%; %, not more | ±0,5 | ±0,3 | ±0,5 | ±0,3 |
– in the range of more than 18-20%; %, not more | ±1,0 | ±0,5 | ±1,0 | ±0,5 |
Power supply | battery, 9V | battery, 9V | battery, 9V | battery, 9V |
Overall dimensions L × W × H, mm | 210 х 75 х 100 | 210 х 75 х 100 | 210 х 80 х 130 | 210 х 80 х 130 |
Weight without/with case, kg | 0,6 / 1,5 | 0,95 / 2,0 | 0,6 / 1,5 | 0,95 / 2,0 |
Model | FarmPoint | FarmPro | SuperPoint | SuperPro |
Type | portable | portable | portable | portable |
Measurement type | dielcometric | resistive | dielcometric | resistive |
Sample preparation | without grinding | with grinding | without grinding | with grinding |
Number of calibrations | 19 | 19 | 20 | 20 |
Measurement range, % | 5…45 | 5…50 | 5…45 | 5…50 |
Permissible values of absolute measurement error: | ||||
– in the range up to 18-20%; %, not more | ±0,5 | ±0,3 | ±0,5 | ±0,3 |
– in the range of more than 18-20%; %, not more | ±1,0 | ±0,5 | ±1,0 | ±0,5 |
Power supply | battery, 9V | battery, 9V | battery, 9V | battery, 9V |
Overall dimensions L × W × H, mm | 210 х 75 х 100 | 210 х 75 х 100 | 210 х 80 х 130 | 210 х 80 х 130 |
Weight without/with case, kg | 0,6 / 1,5 | 0,95 / 2,0 | 0,6 / 1,5 | 0,95 / 2,0 |